Anilam Mini Wizard A163 Manual ~repack~ < PC >
: 0.0005 inches, 0.0001 inches, 0.01 mm, or 0.002 mm (dependent on scale capability)
Rugged cast-aluminum chassis engineered to shield internal circuitry from shop contaminants like oil, chips, and coolant. 2. Front Panel Layout and Keypad Functions
Touch off on the left side of your workpiece and zero the axis. anilam mini wizard a163 manual
Allows the operator to input a specific dimension into an axis instead of zeroing it.
: Clears an erroneous numeric entry or resets the selected axis value to zero. Operational Procedures Basic Zeroing Allows the operator to input a specific dimension
: Instructions on mounting the glass scales (encoders) and configuring the "Resolution" settings (typically 0.0005" or 0.01mm) to ensure the display matches physical tool movement.
Clean glass internally with isopropyl alcohol and a lint-free swab. Incorrect Resolution or Radius/Diameter parameter. Re-enter Setup Mode and change the resolution scale factor. Dead or flickering display segments Failing internal capacitor or logic board solder joint. Clean glass internally with isopropyl alcohol and a
Switches the active display units instantly without losing the current position memory.